E-9

 

TROUBLESHOOTING

 

E-9

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

POSSIBLE

 

RECOMMENDED

 

(SYMPTOMS)

CAUSE

 

COURSE OF ACTION

 

 

 

 

 

 

DEVICENET-PLC CONTROLLED SYSTEM

Analog Inputs don’t respond or don’t

1. Analog Scans Between Updates.

 

1. The DeviceNet tab of the

respond quickly.

 

 

Diagnostics Utility displays the

 

 

 

 

Power Wave’s "Analog Scans

 

 

 

 

Between Updates" and "I/O

 

 

 

 

Scans/Sec." Verify that "Analog

 

 

 

 

Scans Between Updates" is 1/4

 

 

 

 

of "I/O Scans/Sec" value.

 

 

2. Analog In Active Selections.

 

2. From the DeviceNet tab of the

 

 

 

 

Diagnostics Utility, select

 

 

 

 

Configure. Verify in "Analog Input

 

 

 

 

Channels" that the required

 

 

 

 

channels are set active.

 

 

3. Analog Hysteresis.

 

3. From the DeviceNet tab of the

 

 

 

 

Diagnostics Utility, select

 

 

 

 

Configure. Verify in "Analog Input

 

 

 

 

Channels" that the Hysteresis

 

 

 

 

settings are all 0.

 

 

4. Passive Mode.

 

4. The DeviceNet tab of the

 

 

 

 

Diagnostics Utility displays the

 

 

 

 

Power Wave’s passive mode

 

 

 

 

status. If the status needs to be

 

 

 

 

changed, select Configure, and

 

 

 

 

make the necessary modifica-

 

 

 

 

tion.

 

 

 

 

Gas purge not working.

1. Out of gas.

 

1. Verify there is gas available at

 

 

 

 

the input of the gas solenoid.

 

 

2. Gas Purge not asserted.

 

2. From the DeviceNet tab of the

 

 

 

 

Diagnostics Utility, select

 

 

 

 

Monitor. The Monitor window will

 

 

 

 

be displayed. Verify under the

 

 

 

 

"Produced Assembly" that "Gas

 

 

 

 

Purge" is highlighted.

 

 

3. Passive Mode.

 

3. The DeviceNet tab of the

 

 

 

 

Diagnostics Utility displays the

 

 

 

 

Power Wave’s passive mode

 

 

 

 

status. If the status needs to be

 

 

 

 

changed, select Configure, and

 

 

 

 

make the necessary modifica-

 

 

 

 

tion.

 

 

4. Gas Lines.

 

4. Verify nothing is obstructing the

 

 

 

 

flow of gas.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER WAVE® AC/DC 1000

Page 60
Image 60
Lincoln Electric 11226, 11124 manual Analog In Active Selections From the DeviceNet tab, Channels that the required