C-1

ACCESSORIES

C-1

 

 

 

KITS, OPTIONS AND ACCESSORIES

OPTIONAL KITS AND ACCESSORIES

K2282-1 Power Wave System Interface

The optional Power Wave System Interface provides the means to synchronize the AC wave shapes of up to four different arcs to a common carrier frequency. This frequency can range from 10 hertz to 300 hertz, with the most practical range being 10 to 100 hertz. It can also control the phase relationship between arcs to reduce the effects of welding related issues such as "Arc Blow".

K2444-1 CE – C-Tick Filter Kit

This external filter kit is available for the K2344-2Power Wave AC/DC 1000, and mounts directly to the reconnect area on the rear of the machine. The filter is necessary to meet CE conducted emission require- ments.

SOFTWARE TOOLS

The Power Wave AC/DC 1000 is shipped with a CD including software tools and other documents related to the integration, configuration, and operation of the system. The Power Wave Submerged Arc Utilities CD includes the following items and all of the documentation to support them.

 

Name

Purpose

 

 

 

 

Weld Manager

Setup Ethernet address information, and apply security settings.

 

 

 

 

Command Center

AC/DC system tool to observe and log welding operation, verify

 

 

 

DeviceNet welding configuration, and facilitate quality analysis.

 

 

Submerged Arc Cell Configuration

Used to configure and verify a multi-arc or parallel connected power

 

 

 

source (more than one Power Wave per arc) systems.

 

 

Production Monitoring

Allows user to setup Production Monitoring options on the Power Wave

 

 

 

including Email notification, Shift Timers, Wire Package Tracking. Also

 

 

 

provides means to retrieve statistical welding data, generate machine

 

 

 

reports, and update the Power Wave Firmware and Welding Software.

 

 

Diagnostics Utility

Utility to diagnose Power Wave problems, read system information, cali-

 

 

 

brate output voltage and current, test sense leads, and diagnose feed

 

 

 

head issues. Can also setup and verify DeviceNet operation.

 

 

Weld Manager

Palm based utility used to configure, backup and restore various Power

 

 

 

Feed 10A Controller settings (can be used to copy settings from one

 

(Palm Application)

 

 

 

PF-10A to another). Also provides means to retrieve version information

 

 

 

 

 

 

and setup Ethernet address of the local Power Wave system (only those

 

 

 

components directly connected to the PF-10A via ArcLink).

 

 

 

 

POWER WAVE® AC/DC 1000

Page 50
Image 50
Lincoln Electric 11226, 11124 manual KITS, Options and Accessories, Optional Kits and Accessories, Software Tools