INSTALLATION | ||
|
|
|
Table A.7 External I/O S7 (12 pin – terminal block)
PIN | Lead # | Function |
1 | 851 | +15vdc for Trigger group |
2 | 852 | Trigger input |
3 | 853 | Dual procedure input |
4 | 854 | 4 step input (Disabled as of |
5 | 855 | +15vdc for cold inch group (Disabled as of |
6 | 856 | cold inch forward |
7 | 857 | cold inch reverse |
8 | 858 | gas purge input |
9 | 859 | +15vdc for shutdown group |
10 | 860 | shutdown1 input |
11 | 861 | shutdown2 input |
12 | 862 | input B |
Table A.8 Master / Slave I/O and System Interface Output Receptacles (22 Pin – MS bayonet style)
| Pin | Master / Slave Input | Master / Slave Output | Optional System Interface |
|
| (S12) | (S13) | (ARC1, ARC2, ARC3, ARC4) |
| A | Reserved for future use | Reserved for future use | |
| B | Reserved for future use | Reserved for future use | |
| C | Sync In | Reserved for future use | Sync Out |
| D | Sync In | Reserved for future use | Sync Out |
| E | Ready In | Ready In | |
| F | Ready In | Ready In | |
| G | Polarity Out | Polarity Out | |
| H | Polarity Out | Polarity Out | |
| I | Ground | ||
| J | Reserved for future use | Reserved for future use | |
| K | Reserved for future use | Reserved for future use | |
| L | +40v (COM) | Reserved for future use | |
| M | +40v ("+") | Reserved for future use | |
| N | Reserved for future use | Reserved for future use | |
| P | Reserved for future use | Reserved for future use | |
| R | Reserved for future use | Reserved for future use | |
| S | Reserved for future use | Reserved for future use | |
| T | Drain (ethernet) | Drain (ethernet) | |
| U | Kill Out | Kill Out | |
| V | Kill Out | Kill Out | |
| W | Work voltage sensing (21) | Work voltage sensing (21) | |
| X | Electrode Voltage Sensing (67) | Electrode Voltage Sensing (67) | |
|
|
|
|
|
Table A.9 Ethernet Connector S9 (8 pin –
PIN | Function |
1 | Transmit + |
2 | Transmit - |
3 | Receive + |
4 | |
5 | |
6 | Receive - |
7 | |
8 |
POWER WAVE® AC/DC 1000