A-10

PULSE WAVE SHAPING PRINCIPLES

Appendix A

5. Adjust the Start Control Parameters (Optional)

The start control parameters can be adjusted to define how the welding machine will respond when the arc is struck.

To view the start control window, click on the button on the Waveform Editor screen. Adjust the start control parameters to accommodate your welding application and per the following parameter descriptions.

STRIKE

STRIKE

PEAK TIME

Start Control - Pulse

Start Control

For Wire Feed Speed 150

Stage 1 : Wire Run In

Open Circuit Volt 48.0

PEAK AMPS

OPEN

CIRCUIT START TIME VOLTS

ARC

STRIKE

AVERAGE

START

AMPS @

START

VOLTS

Stage 2 : Striking Pulse

Strike Peak Time

2.0

Strike Peak Amps

550.0

Stage 3 : Arc Length Control

Start Volt

28.0

Start Time

50

Stage 4 : Current Control

Start Amps 50

27850035

Open circuit voltage: Sets the power source output voltage for the torch idle condition (the welding machine is on, but not welding).

Strike peak amps: Adjust this parameter to set the peak level for the arc-strike current spike.

Strike peak time: Adjust this parameter to set the duration of peak current for the arc-strike current spike.

Starting volts: Adjust this parameter to set the gun voltage to be maintained during the arc starting routine.

Starting time: Adjust this parameter to set the duration of the arc starting routine.

Starting amps: Adjust this parameter to set the average current level during starting.

WAVE DESIGNER

Page 42
Image 42