F-6

TROUBLESHOOTING & REPAIR

F-6

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

Output turns on momentarily, then 1.

Check the input voltages and

1. Check Local/Remote switch (S3)

switches off and repeats cycle.

reconnection procedures. Make

and associated wiring for loose or

 

 

 

sure the input voltage is correct

faulty connections.

 

 

 

 

for the machine. See Input

 

 

 

 

 

Voltage Reconnect Procedure. 2. Check Mode Switch (S2) and

 

 

 

 

 

associated wiring for loose or

 

 

2.

Check or replace remote control

faulty connections.

 

 

 

 

device. (If used)

 

 

 

 

 

 

3. If the machine is connected for

 

 

 

 

380VAC input or higher, perform

 

 

 

 

the Capacitor Balance Test.

 

 

 

 

 

4. The power board may be faulty.

 

 

 

 

Replace.

 

 

 

 

 

5. The control board may be faulty.

 

 

 

 

Replace.

 

Remote output control not

1.

Make sure the Local/Remote

1.

Check the Local/Remote switch

functioning. The machine operates

 

switch (S3) is in the REMOTE

 

(S3) and the associated wiring.

normally on LOCAL control.

 

position.

 

See wiring diagram.

 

2.

The remote control device may

2.

Check for loose or faulty

 

 

be faulty. Replace.

 

connections at the remote control

 

 

 

 

receptacle.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

INVERTEC V250-S

Page 38
Image 38
Lincoln Electric V250-S service manual Capacitor Balance Test