Lincoln Electric V250-S service manual Main Transformer Secondary Leads

Models: V250-S

1 118
Download 118 pages 30 Kb
Page 99
Image 99

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-67

TROUBLESHOOTING & REPAIR

F-67

 

 

MAIN TRANSFORMER REMOVAL AND REPLACEMENT

(MACHINE CODES BELOW 10150)

(continued)

MAIN TRANSFORMER

SECONDARY LEADS

Figure F.21 Main Transformer Left Side

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

6.Disconnect and clear the shunt sensing leads from the control board (plug J4).

7.Disconnect the thermostat leads from the thermostat mounted on the shunt assembly.

8.With the 3/4” wrench remove the shunt assembly from the negative output terminal. Take note of the by- pass connection on the negative ter- minal. Clear the shunt to allow access to the main transformer and lead connections. Cut any neces- sary cable ties.

9.With the 3/4” wrench remove the two secondary leads from the positive output terminal. Take note of the by- pass connection on the positive ter- minal.

10.Locate and cut the necessary wire ties and slide the sleeving from the four transformer secondary and reactor lead splices.

11.With slot head screwdriver and 3/8” nut-driver remove the two reactor leads from output rectifier leads. Label the leads for reassembly.

12.Using the 7/16” wrench remove the secondary leads from the output rectifier leads.

Label the leads and note washer and lead placement for reassembly.

13.With 3/8” wrench remove the two screws mounting the transformer assembly to the base of the machine. See Figure F.22. Note: The machine will have to be tilted on its side to gain access to the bottom of the unit.

INVERTEC V250-S

Page 99
Image 99
Lincoln Electric V250-S service manual Main Transformer Secondary Leads