F-4

TROUBLESHOOTING & REPAIR

F-4

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

Major physical or electrical damage

Contact your local Lincoln

Contact Lincoln Electric Service

 

is observed when cover wrap-around

Authorized Field Service Facility.

Department (216)-383-2531

or

 

is removed.

 

 

1-800-833-9353

 

 

 

 

 

 

The machine is dead - no output -

1. The input power switch must be

1. The power switch (S1) may be

 

no fan.

 

 

in the ON position.

faulty. Check or replace.

 

 

 

 

2.

Make sure the input voltage is

2. Check for loose or broken leads

 

 

 

 

correct for the machine.

between the power switch (S1)

 

 

 

 

 

and the input rectifier D9. See

 

 

 

3.

If the machine is set for single-

wiring diagram.

 

 

 

 

 

phase operation, inspect to

 

 

 

 

 

 

assure that the WHITE and

3. Perform the Auxiliary

 

 

 

 

 

BLACK leads are connected

Transformer Test.

 

 

 

 

 

properly and the RED lead is not

 

 

 

 

 

 

connected and is insulated.

 

 

 

 

 

4. Check that the input voltage set-

 

 

 

 

 

 

up switch and jumper “A” (the

 

 

 

 

 

 

reconnect auxiliary jumper) are in

 

 

 

 

 

 

the proper position for the input

 

 

 

 

 

 

voltage being applied. Refer to

 

 

 

 

 

 

Input Voltage Reconnect

 

 

 

 

 

 

Procedure in the Installation

 

 

 

 

 

 

Chapter.

 

 

 

 

 

5. Check continuity of the 0.6-amp

 

 

 

 

 

 

slow blow fuse located on the

 

 

 

 

 

 

reconnect panel.

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

INVERTEC V250-S

Page 36
Image 36