F-13

TROUBLESHOOTING & REPAIR

F-13

 

 

 

AUXILIARY TRANSFORMER TEST (continued)

 

 

TABLE F.1 Auxiliary Transformer Test Points

 

 

 

 

 

 

 

TEST POINT

TEST POINT

EXPECTED VOLTAGE

 

 

 

 

 

 

 

H1 (1J7)

H2 (4J7)

200 - 208VAC

 

 

 

 

 

 

 

H1 (1J7)

H4 (3J7)

380 - 415VAC

 

 

 

 

 

 

 

H1 (1J7)

H5 (6J7)

440 - 460VAC

 

 

 

 

 

 

 

RED LEAD (1J1)

RED LEAD (3J1)

18VAC (SECONDARY)

 

 

On Control Board

On Control Board

 

 

 

 

 

 

 

7.If the correct test voltages are pre- sent the auxiliary transformer is good.

8.If any of the voltages are missing or very low, with the proper primary voltage applied, the auxiliary trans- former may be faulty. Replace.

9.If the auxiliary transformer tests good but does not function when connect- ed to the V250-S check the harness wiring to the auxiliary transformer. See wiring diagram.

INVERTEC V250-S

Page 45
Image 45
Lincoln Electric V250-S service manual Table F.1 Auxiliary Transformer Test Points