PROCEDURE

1.Remove input power to the V250-S.

2.Perform Filter Capacitor Discharge Procedure detailed in Maintenance Section.

3.Locate main transformer and associ- ated primary leads. See Figure F.20.

4.Disconnect transformer primary leads #201, #204, #205 and #208 from the power board.

Note: Leads #204 and #205 will have to be removed from the T3 cur- rent transformer. Cut any necessary

cable ties. Be sure to note the direction that the leads are thread- ed through the current trans -

former. Upon reassembly the leads must be threaded through correctly.

5.Locate main transformer and associ- ated secondary leads, reactor leads, and shunt connections. See Figure F.21.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

201

204

208 205

T3 CURRENT TRANSFORMER

MAIN TRANSFORMER

Figure F.20 Main Transformer Right Side