TOC

TOC

F-16

TROUBLESHOOTING & REPAIR

F-16

 

 

INPUT RECTIFIER TEST (continued)

Return to Section

Return to Master

TEST PROCEDURE

1.Remove main input power to the V250-S.

2.Perform Filter Capacitor Discharge Procedure detailed in Maintenance Section.

3.Locate Input Rectifier (D9) and lead locations.

4.With the Phillips head screwdriver remove leads #207, 207A and #209 from the rectifier. See Figure F.2.

5.Use the analog ohmmeter to perform the tests detailed in Table F.2. See wiring diagram.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

#207

#207A

A

B

C

#209

Figure F.2 Input Rectifier and Leads.

INVERTEC V250-S

Page 48
Image 48
Lincoln Electric V250-S service manual Input Rectifier Test, Test Procedure