TROUBLESHOOTING & REPAIR | ||
|
|
OUTPUT DIODES TEST (continued)
Return to Section
Return to Master
TEST PROCEDURE
1.Remove main input power to the
2.Locate the output terminals on the front panel of the machine. See Figure F.4.
3.Remove any output cables and load from the output terminals.
4.Using the analog ohmmeter test for more than 200 ohms resistance between positive and negative out- put terminals. Positive test lead to the positive terminal; Negative test lead to the negative terminal. See Figure F.5.
NOTE: THE POLARITY OF THE TEST LEADS IS MOST IMPORTANT. IF THE TEST LEADS POLARITY IS NOT CORRECT THE TEST WILL HAVE ERRONEOUS RESULTS.