F-33

TROUBLESHOOTING & REPAIR

F-33

 

 

CONTROL BOARD VOLTAGE TEST (continued)

TABLE F.5. Control Board Voltage Test Points.

 

 

ACCEPTABLE

 

TEST DESCRIPTION

TEST POINTS

VOLTAGES

TEST CONDITIONS

 

 

 

 

The 18VAC from the auxil-

Red lead (1J1)

18VAC

The correct input voltage

iary transformer to the con-

to

Note: voltage will vary with

applied to the V250-S and

trol board.

Red lead (3J1)

input line voltage.

the input power switch (S1)

 

 

 

in the ON position.

 

 

 

 

Remote trigger circuit test.

Lead #318 (4J5)

0 VDC.

When remote trigger circuit

(#2 and #4)

to

 

is “closed”.

 

Lead #322 (1J5)

 

 

 

 

 

 

Remote trigger circuit test.

Lead #318 (4J5)

12VDC.

When remote trigger circuit

(#2 and #4)

to

 

is “open”.

 

Lead #322 (1J5)

 

 

 

 

 

 

Shunt feedback milli-volt

White lead (2J4)+

100 mV.

Machine loaded to 120

check.

to

 

Amps

 

Black lead (1J4)-

 

 

 

 

 

 

Check for 15VDC control

Lead #303 (7J3)+

15VDC.

The correct input voltage

board supply voltage.

to

 

applied to the V250-S and

 

Lead #375 (1J3)-

 

the input power switch (S1)

 

 

 

in the ON position.

 

 

 

 

INVERTEC V250-S

Page 65
Image 65
Lincoln Electric V250-S service manual Table F.5. Control Board Voltage Test Points, 18VAC