PROCEDURE
1.Remove input power to the
2.Perform Filter Capacitor Discharge Procedure detailed in Maintenance Section.
3.Locate the input rectifier and the leads connected to it. See Figure F.16.
4.Identify and mark the leads connect- ed to the rectifier terminals.
5.With the Phillips head screwdriver remove the eight leads connected to the rectifier terminals.
6.Using the 3/16” Allen wrench and 7/16” box wrench remove the two cap head screws, washers and nuts mounting the input rectifier bridge to the center panel assembly.