7.Carefully remove the input rectifier bridge.

8.When installing a new input rectifier apply a thin coating of Dow Corning 340 Heat Sink Compound (Lincoln E1868) to the mating surfaces. Torque the mounting cap screws and nuts to 44 IN-LBS.

9.Reconnect the eight leads to the cor- rect terminals and torque the phillips head screws to 31 IN-LBS.