Lucent Technologies 585-310-575 manual Alarm Code Event ID ELA-shadow03

Models: 585-310-575

1 80
Download 80 pages 27.59 Kb
Page 73
Image 73

SHADOW Resource Type

Alarm Code: 3

Event ID: ELA-shadow03

Alarm Level:

Warning

Description: Shadow mailbox data corrupt, re-enter or restore.

Repair Action:

There are two recovery methods:

Access the Set Up Enhanced-List System Data window and re-enter the shadow mailbox extension and community ID. If a shadow mailbox exists at the extension entered, the system displays a system prompt to that effect. If a shadow mailbox does not exist at the extension entered, a new mailbox will be created.

Restore data from the most recent backup of system data. See Chapter 3, “Common System Procedures,” in your maintenance book for instructions about restoring data. If you would prefer to have assistance with this restore, contact your remote maintenance center.

Alarm Code: 4

Event ID: ELA-shadow04

Alarm Level:

Warning

Description: Shadow mailbox does not allow trusted-server access.

Repair Action:

1.In AUDIX, enter ch cos ELA_Class_of_Service_Name/Number

2.Verify that the Trusted Server Access? field is set to y

3.Enter di sub shadow_mailbox_extension

4.Verify the Class of Service field is the appropriate cos. If it is, call 1-800-56 AUDIX for help.

Alarm Code: 5

Event ID: ELA-shadow05

Alarm Level:

Warning

Description:

Shadow mailbox does not exist at expected extension.

Issue 1 July 1997 63

Page 73
Image 73