Lucent Technologies 585-310-575 manual Shadow Resource Type, Alarm Code Event ID ELA-shadow01

Models: 585-310-575

1 80
Download 80 pages 27.59 Kb
Page 72
Image 72

Alarms

SHADOW Resource Type

Alarm Code: 1

Event ID: ELA-shadow01

Alarm Level:

Warning

Description: Shadow mailbox data lost, re-enter or restore.

Repair Action:

There are two recovery methods:

Access the Set Up Enhanced-List System Data window and re-enter the shadow mailbox extension and community ID. If a shadow mailbox exists at the extension entered, the system displays a system prompt to that effect. If a shadow mailbox does not exist at the extension entered, a new mailbox will be created.

Restore data from the most recent backup of system data. See Chapter 3, “Common System Procedures,” in your maintenance book for instructions about restoring data. If you would prefer to have assistance with this restore, contact your remote maintenance center.

Alarm Code: 2

Event ID: ELA-shadow02

Alarm Level:

Warning

Description: Shadow mailbox corrupt, re-enter or restore.

Repair Action:

There are two recovery methods:

Access the Set Up Enhanced-List System Data window and re-enter the shadow mailbox extension and community ID. If a shadow mailbox exists at the extension entered, the system displays a system prompt to that effect. If a shadow mailbox does not exist at the extension entered, a new mailbox will be created.

Restore data from the most recent backup of system data. See Chapter 3, “Common System Procedures,” in your maintenance book for instructions about restoring data. If you would prefer to have assistance with this restore, contact your remote maintenance center.

62Issue 1 July 1997