REGISTRY Resource Type

2.Verify/administer the screen information, as required.

3.Repeat for the delivery trusted server.

4.Enter ch imapi and verify/administer as required.

5.When complete, enter the correct information in the Set Up Enhanced-List System Data window.

REGISTRY Resource Type

Alarm Code: 1

Event ID: ELA-registry01

Alarm Level:

Warning

Description: E-list registry lost, re-enter or restore. The ELA software has detected that registry database has disappeared.

Repair Action:

1.Re-administer the registry:

a.Go to the Administer Enhanced-Lists window.

b.Use (F4) NEW E-LIST to re-enter the name of each Enhanced List, one at a time. (The individual members do not need to be re-entered.)

See Lucent INTUITY™ Messaging Solutions Release 4 Administration, 585-310-564 for more detailed procedures.

2.If the alarm persists, restore system data from the nightly backup. See Chapter 3, “Common System Procedures,” in your maintenance book for instructions about restoring data. If you would prefer to have assistance with this restore, contact your remote maintenance center.

Alarm Code: 2

Event ID: ELA-registry02

Alarm Level:

Minor

Description: Unable to write updated E-list registry.

Repair Action:

This alarm requires intervention from the remote maintenance center.

Issue 1 July 1997 61

Page 71
Image 71