Axiom Pro User Guide | 46 |
Edit Mode > MIDI
press 4
This page contains a variety of options relating to MIDI.
Parameter: SysEx
Value Range: Off, O, A, A&O, B, B&O, A&B, All
SysEx messages can be transmitted on any combination of Axiom Pro ports:
•A Axiom Pro 6112 USB A
•B Axiom Pro 6112 USB B
•O Axiom Pro 6112 MIDI Out (External MIDI port)
•All MIDI data is transmitted on all ports
•Off MIDI data is not transmitted
✓NOTE: SysEx messages are not MIDI channel specific, instead, a “Device ID” number is used. If a SysEx message is sent out of a specific Axiom Pro MIDI port, all connected devices (or software) will receive that data. More info about SysEx transfers and Device IDs can be found below.
Parameter: | DevID |
Value Range: | |
| This parameter sets the “Device ID” code used when transmitting SysEx messages from Axiom Pro. |
| The default value is 127. |
| The default setting of 127 lets your Axiom Pro respond to all incoming SysEx messages that are |
| compatible with Axiom Pro controllers. However, if you change the Device ID to any other value, |
| your Axiom Pro will only respond to SysEx messages that contain the same Device ID number. This |
| is useful in situations in which multiple Axiom Pro controllers are connected to your sequencer but |
| you would like to send SysEx information to a specific controller with a unique Device ID number. |
12The 25 and