VIDEO CONVERT

FUNCTIONS

NAMES AND

CONNECTIONS

BASIC

OPERATION

BASIC

CONNECTIONS

ADVANCED

SETUP

OPERATION

ADVANCED

TROUBLESHOOTING

OTHERS

ENGLISH

ADVANCED OPERATION

VIDEO CONVERT

ANALOG VIDEO CONVERSION

This unit is equipped to convert video signals for monitor output. Because of this, indifferent of the connection (VIDEO, S-VIDEO, COMPONENT VIDEO) between the playback device and this unit, listening and viewing are possible with a single higher grade cable between the MONITOR OUT terminal of the unit and the monitor.

UP-CONVERSION FROM ANALOG VIDEO SIGNALS TO HDMI

The up-conversion feature of this unit can output the input analog video signals (for component video signals of 480i/576i, 480p/576p, 1080i and 720p resolution, and S-Video and Video (composite) of 480i/576i resolution) to the HDMI MONITOR terminal.

Notes

HDMI video input is only output to the HDMI MONITOR OUT terminal of the unit. If connecting a playback device such as a DVD player to the HDMI input jack, connect the HDMI MONITOR OUT terminal of the unit to a TV monitor.

This mode is unavailable for the REC out terminal.

This mode is unavailable for still picture, fast forward and reverse play on video component.

If, while attempting to use the video convert feature, the unit cannot synchronize with the display device, “NO SIGNAL” appears on the monitor or noise is generated, this feature cannot be used. All of these signs are caused by equipment incompatibility; there is nothing wrong with the unit.

If this occurs, set “VIDEO CONVERT” in the “VIDEO SETUP” menu to “DISABLE”. Next, connect the video input signal to the display component via the MONITOR OUT terminal under VIDEO and the S-video input signal to the display component via the MONITOR OUT terminal under S-VIDEO.

The video convert feature constantly monitors input video signals and determines whether to convert the input signals or not. However, some input video signals cannot be detected correctly. If this occurs, set “VIDEO CONVERT” in the “VIDEO SETUP” menu to “DISABLE”.

CONNECTION EXAMPLE

When a monitor is connected to the HDMI MONITOR OUT terminal of the unit

VIDEO

 

or S-VIDEO

 

or component

 

or HDMI

HDMI

Notes

If the resolution of the component video signal input from the playback device is other than 480i/576i, 480p/576p, 1080i or 720p, images are not output from the HDMI MONITOR OUT terminal of the unit.

If the resolution of the Video signal input from the playback device is other than 480i/576i, images are not output from the HDMI MONITOR OUT terminal of the unit.

When a monitor is connected to the VIDEO MONITOR OUT terminals of the unit

VIDEO

VIDEO

or S-VIDEO

 

or component

 

HDMI

 

Notes

The HDMI video signal input from the playback device is not output from the VIDEO MONITOR OUT terminals of the unit.

If the resolution of the component video signal input from the playback device is other than 480i/576i, it is not output from the VIDEO MONITOR OUT terminals of the unit.

When a monitor is connected to the

COMPONENT VIDEO MONITOR OUT terminal of the unit

VIDEO

 

or S-VIDEO

component

or component

 

HDMI

 

Note

The HDMI video signal input from the playback device is not output from the COMPONENT VIDEO MONITOR OUT terminal of the unit.

Note of OSD menu system

The setup menu can be displayed through all video out terminals (“HDMI”, “COMPONENT” and “VIDEO”).

I/P CONVERT

The video circuit of the unit is equipped with an I/P conversion feature.

When this feature is on, 480i/576i analog video signals (VIDEO, S-VIDEO or COMPONENT VIDEO) input from a playback device can be converted to 480p/576p and progressively output to the COMPONENT VIDEO or HDMI MONITOR OUT terminals of the unit.

(For setting instructions, see page 35)

Note

WhenamonitorisconnectedtotheHDMIMONITOR OUT terminal, and HDMI RESOLUTION is set to 720p, 1080i, 1080p, or AUTO, the I/P CONVERT for COMPONENT VIDEO OUTPUT does not function.

HDMI OUT (SR6004 ONLY)

HDMI OUTPUT 1 or 2 can be selected and used with this unit.

Each time the HDMI button on the remote controller is pressed, OUTPUT 1 is switched to OUTPUT 2 or vice versa.

HDMI OUT 1 and HDMI OUT 2 cannot be output simultaneously.

H D M I - O = O U T 1

HDMI RESOLUTION

This function is used to output the analog video signal to HDMI as follows.

480i/576i signals can be converted to 480p/576p, 1080i, 720p or 1080p signals, while 480p/576p signals can be converted to 1080i, 720p or 1080p signals.

720p signals can be converted to 1080i or

1080p.

1080i signals can be converted to 1080p.

The output resolution can be set for HDMI OUT 1 and HDMI OUT 2. (SR6004 only)

Notes

Do not set to 1080i, 720p or 1080p when connected to a monitor that does not support 1080i, 720p or 1080p signals. The SETUP MENU will not be displayed. If the SETUP MENU is not displayed, change settings while viewing the main unit display panel.

The resolution of analog component output cannot be changed.

HDMI OUT 1 and HDMI OUT 2 cannot be output simultaneously. (SR6004 only)