B-RAID Level Comparison Table

Appendix B: RAID Level Comparison Table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID

Description

 

 

 

 

 

Min.

Max.

Capacity

Data

 

 

Data

 

 

 

I/O

 

 

 

 

Level

 

 

 

 

 

 

 

Drives

Drives

 

Reliability

 

 

Transfer Rate

 

Request Rates

 

 

Span

Also known as disk spanning. Data

1

4

(N)

No data protection

 

Same as a single disk

same as a single disk

 

 

is distributed sequentially to all

 

 

Disks

 

 

 

 

 

 

 

 

 

 

 

 

 

drives. There is no data protection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Also known as striping

 

 

1

4

(N)

No data

 

 

Very High

 

 

Very High for

 

 

 

Data

distributed

across

multiple

 

 

Disks

Protection

 

 

 

 

 

 

Both Reads and Writes

 

drives in the array simultaneously.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

There is no data protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Also known as mirroring

 

 

2

4

1/(N )

Lower than

RAID

6,

Reads are higher

 

Reads

are

twice

faster

 

All data replicated on N Separated

 

 

Disks

Higher than RAID 5

 

Than a single disk;

 

than a single disk;

 

 

 

disks. N is always a multiple of 2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is a high availability Solution,

 

 

 

 

 

 

Writes similar to a sin-

Write

are similar

to

a

 

but due to the 100% data duplication,

 

 

 

 

 

 

gle disk

 

 

 

single disk.

 

 

 

 

it is also a costly solution.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Also known as striped mirroring. Data

4

4

1/2 (N)

Lower than

RAID

6,

Reads

are

similar

to

Reads

are

similar

to

 

and parity information is subdivided

 

 

Disks

higher than RAID 5

 

RAID 0

 

 

 

RAID 0

 

 

 

 

and distributed across all disks. This

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is a high availability Solution, but

 

 

 

 

 

 

Writes

are

similar

to

Writes are similar to sin-

 

due to the 100% data duplication, it

 

 

 

 

 

 

single disk

 

 

gle disk

 

 

 

 

is also a costly solution.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Also

known

Block-Interleaved

3

5

(N-1)

Lower than RAID 1, 10

Reads are similar to

 

Reads are similar to

 

 

distributed Parity. Data and parity

 

 

Disks

 

 

 

RAID 0;

 

 

RAID 0;

 

 

 

 

information

is

subdivided

and

 

 

 

Higher than

a single

 

 

 

 

 

 

 

 

 

 

distributed across all disk. Parity

 

 

 

drive

 

 

Writes are slower than

Writes are slower than a

 

must be the equal to the smallest

 

 

 

 

 

 

RAID 0

 

 

 

single disk.

 

 

 

 

disk capacity in the array. Parity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

information normally stored on a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dedicated parity disk.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Also known as dual parity. Similar

4

5

(N-2

Highest Reliability

 

Reads are similar to

 

Reads are similar to

 

 

to RAID 5, but does two different

 

 

Disks)

 

 

 

RAID 0;

 

 

 

RAID 0;

 

 

 

 

parity computations or the same

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

computation on overlapping subsets

 

 

 

 

 

 

Writes are slower than

Writes are slower than a

 

of the data. The RAID 6 can offer

 

 

 

 

 

 

RAID 5

 

 

 

single disk.

 

 

 

 

fault

tolerance

greater that

RAID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 or RAID 5 but only consumes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the capacity of 2 disk drives for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distributed

parity

data

reliability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

similar to RAID 0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MaxNAS Owner’s Manual

60

Page 60
Image 60