5 E1 Daughter Card

E1 Commands

Three E1 commands are available (some that result in a displayed menu) for displaying and changing E1 provisioning parameters.

The screen below displays the MultiComm Manager software interface:

Command Example

Examples of using the E1STATUS, E1SETUP, E1CFG commands with the MR96000 Controller are provided below. Note that you can use the hyphen key to back up to change a selection, or use the 'Q' key to quit at any time.

1.Enter the E1STATUS xy command (where xy is equal to the slot number of the E1 Daugter card) to check on the status and settings for displaying and changing E1 provisioning parameters. An example of using the E1STATUS, E1SETUP, and E1CFG commands to correct an E1 problem is provided below. Note that you can use the hyphen key to back up to change a selection, or use the ‘Q’ key to quit at any time.

A:\#e1status 9b

E1 Card Status:

Channel Polling Interval (Sec):20

Error Threshold:10

Disconnect Timeout (sec):11

Framing Format:CRC4

Line Coding:Alternate Mark Inversion (AMI)

Signal Options:R2 MF

DNIS-digits (1-64 or 0 for auto):0

Country Selection:ITU

Line Buildout:120 Ohm

LED Information:Red Alarm, Sync Loss

Model:RAS9600-E1

Version:2.00c/1.06