Chapter 5 Programming

©

National Instruments Corporation 5-31 AT-MIO-16X User Manual

Figure 5-9. Pulsed Cyclic Waveform Programming

In this mode, Counter 1 counts the programmed number of cycles before terminating the sequence. Counter 2 then begins counting the time between cycles, the cycle interval, then restart s the sequ ence. T his
END
START
Clear the analog output
circuitry including the
DAC FIFO
Program the update
interval counter
Set the A4RCV bit in
Command Register 2
Set the waveform
generation mode
Service update requests
Clear the A4RCV
bit in Command
Register 2
Yes
No
Enable updating
Program the cycle counter
Select the update counter
via RTSI programming
Program the cycle interval
counter
Internal