NEC Versa Series manual Beep Codes, Solving System Problems, Post Error Messages

Models: Versa Series

1 150
Download 150 pages 55.12 Kb
Page 104
Image 104
Beep Codes

 

Post Error Messages

 

 

Message

Resolution

Off Board Parity Error

Parity error in an expansion slot. Contact your NEC

 

Computers service representative to be sure that the

 

memory module is installed correctly.

 

The error format is:

 

OFF BOARD PARITY ERROR

 

ADDR(HEX) = (XXXX)

 

XXXX is the hex address where the error occurred.

On Board Parity Error

Parity error in system board memory. Contact your

 

NEC Computers service representative for service.

Parity Error ????

Parity error in system memory at an unknown address.

 

Contact your NEC Computers service representative

 

for service.

 

 

Beep Codes

Fatal errors that occur during POST are communicated through a series of beeps. All beep code errors, except beep code 8, are fatal errors and do not allow the system to continue to boot.

If beep codes occur during POST, check the items in the Problem Checklist (at the start of this chapter), verify that all the hardware is set up properly and securely connected, and try rebooting. If you still get a beep code, go to the section “If You Need Assistance” at the end of this chapter.

Beep Codes are listed in the table that follows.

 

Beep Codes

 

 

 

Number of

 

 

Beeps

Error

Description

1

Refresh Failure

The memory refresh circuitry on the

 

 

motherboard is faulty.

2

Parity Error

Parity error in the first 64 KB of

 

 

memory.

3

Base 64 KB Memory

Memory failure in the first 64 KB.

 

Failure

 

4

Timer Not Operational

Memory failure in the first 64 KB of

 

 

memory or Timer 1 on the

 

 

motherboard is not functioning.

 

 

 

10-6 Solving System Problems

Page 104
Image 104
NEC Versa Series manual Beep Codes, Solving System Problems, Post Error Messages