Reference Guide for the Model XM128 ISDN Digital Modem
Table | Extended |
| |||||
|
|
|
|
|
| ||
Command | Bit | Decimal | Hexadecimal | Function and | Default or | ||
description | reference | ||||||
|
|
|
| ||||
|
|
|
|
|
| ||
S82= |
|
|
| ISDN B channel protocol | Bn | ||
|
|
|
|
|
| ||
|
| 60 |
| V.120 64000 |
| ||
|
|
|
|
|
| ||
|
| 61 |
| V.120 56000 |
| ||
|
|
|
|
|
| ||
|
| 62 |
| X.75 64000 Transparent |
| ||
|
|
|
|
|
| ||
|
| 63 |
| X.75 56000 Transparent |
| ||
|
|
|
|
|
|
| |
|
| 64 |
| X.75 | 64000 T.70 |
| |
|
|
|
|
|
|
| |
|
| 65 |
| X.75 | 56000 T.70 |
| |
|
|
|
|
|
| ||
|
| 72 |
| V.110 64000 |
| ||
|
|
|
|
|
| ||
|
| 73 |
| V.110 56000 |
| ||
|
|
|
|
|
| ||
|
| 74 |
| PPP async to sync 64K |
| ||
|
|
|
|
|
| ||
|
| 75 |
| PPP async to sync 56K |
| ||
|
|
|
|
|
| ||
|
| 76 |
| SLIP to sync HDLC conversion |
| ||
|
|
|
| 64K |
|
| |
|
|
|
|
|
| ||
|
| 77 |
| SLIP to sync HDLC conversion |
| ||
|
|
|
| 56K |
|
| |
|
|
|
|
|
| ||
S83= |
|
|
| Bitmapped register | +000 | ||
|
|
|
|
|
| ||
| 0 | 0 | 0 | Disables loopback 4 test. | CP0 | ||
|
|
|
|
|
| ||
|
| 1 | 1 | Enables loopback 4 test. | CP1 | ||
|
|
|
|
|
| ||
| 2 | 0 | 0 | ISDN without V.42bis | &K00 | ||
|
|
|
|
|
| ||
|
| 4 | 4 | ISDN with V.42bis, if applicable | &K44 | ||
|
|
|
|
|
| ||
| 0 * | 0 | ATDs, ATDPs, and ATDTs are | &O0 | |||
|
|
|
| mapped to ATDMs. |
| ||
|
|
|
|
|
| ||
|
| 32 | 20 | ATDs, ATDPs, and ATDTs are | &O2 | ||
|
|
|
| mapped to ATDIs. |
| ||
|
|
|
|
|
| ||
|
| 48 | 30 | ATDs, ATDPs, and ATDTs are | &O3 | ||
|
|
|
| mapped to ATDBs. |
| ||
|
|
|
|
|
|
|
Status Registers and Result Codes |