Installing the server and connecting the peripheral devices

Standard 1.07

2Connect the other end of the DC power cable to the PDU. Use the supplied clips and screws to secure the plugs.

The following photograph shows the keyed plug of the DC power cable. This plug connects to the PDU:

Note: If you are not using a Nortel-supplied PDU, have a qualified electrician connect the cable appropriately to your DC power plant. The 1002rp uses a negative 48 V power supply, therefore the red cable is negative (-48 V) and the black cable is the ground (GND).

3Turn on the PDU.

To start the server

1Press the server power switch to start the server.

2Observe the Power-On Self Test (POST) and initialization messages on the monitor.

3Let the mini-setup sequence run until you are prompted to login to the operating system.

Note: The system may perform multiple reboots. This is normal.

4Ensure that the operating system logon window appears on the monitor.

Note: If the logon window does not appear, refer to the 1002rp Server Maintenance and Diagnostics (555-7101-206) guide for troubleshooting instructions.

78

CallPilot

Page 78
Image 78
Nortel Networks 1002rp manual To start the server