4-9
Chapter 4 Troubleshooting Procedures
NortelNetworks 5399 Access Switch HardwareInstallation Guide
Table4-3. Errors from Last ERPC LayerInvocation
Table4-4. Errors from Last Read Request
Error Description
H/We rrors TheRemote Access Concentrator sensed a hardware error
duringmessage transmission or reception. This error
indicatesa fault with the Remote Access Concentrator LAN
interface.Use the net command to isolate the problem (see
“net”on page 3-19).
Msgsfrom
wronghost TheRemote Access Concentrator receiveda message from
anincorrect host. This indicates that the Remote Access
Concentratorreceived, and ignored, an unsolicited packet.
Rsp T/O’s The Remote Access Concentrator neverreceived a
correctlyformatted response from the correct host, or any
responsefrom anyload server hosts.
Msgsof
wrongtype The correct host sent a message to the RemoteAccess
Concentrator,but the message was not a correctly
formattedresponse to the transmitted request.
Error Description
Msgswith wrong
size Thecorrect host responded to the Read Request, but
thedata size is incorrect.
ERPC layererrors See Tab le 4-3 .
Abortsrx’d Thehost’s BFS transmitted an abort in response to
theRemote Access Concentrator’s Read Request.
Runerpcd –D on the host to obtain more
information.