Nortel Networks 5399 Access Switch Hardware Installation Guide
Chapter2 Installingthe Model5399 Remote Access ConcentratorModule
2-20
6. Pressthe space bar within 10 seconds.
After a fewseconds, the following message is displayed:
Monitor Mode selected, please w ait for Confidence tests
to complete.
After abouta minute, the following message is displayed,
followedby themonitor prompt:
System Reset - Entering Monitor M ode
monitor::
7. If you want to clear out the stored parameters from a
previouslyused slot (resetthe hub slot), continue onwith
Step 8. If you do not want to reset the hub slot (if, for
example, youare performing a hot swap), skip to Step 16.
8. On the service port terminal, press then -T to
display the Slot Selection menu.
9. Press s.
The SupervisoryModule Main Menu is displayed.
10. Press mtoselecttheModuleInformationmenu.
The followingprompt is displayed:
Enter slot # (1-14):
11. Enter the slot number of the module you want to boot.
The module informationand status are displayed and you are
prompted to resetthe module,set the module configuration to
default,or return to the previous menu.
12. Press dto select the module configuration default.
The followingmessage is displayed:
Are you sure you want to set module DEF AULT
configuration? (Y/N):
Enter Control