i2022 ISDN Teleset
TERMINATING RESISTORS
The i2022Teleset S Interface module has
NOTE: The S Interface Module must be removed from the Teleset to gain access to the option switches.
POINT-TO-POINT CIRCUITS
A
Figure 6: Terminating Resistor Range
PASSIVE-BUS OR MULTIPOINT
These may be new terms to you, so we will define them so you can better understand their meaning. Passive Bus means that you can connect several devices to the same Basic Rate Interface (ISDN line). Improperly set Terminating Resistors account for many of the problems with ISDN service. The “short version” of this explanation is that both ends of a bus or circuit must be terminated.
Your choices of terminating resistance are two: none or 100 Ohms. The idea is to terminate both ends of the bus. Set the resistors to ON at both ends of the bus.
The best advice is to follow the instructions given by the NT1 manufacturer and those of your terminating devices.
In the following configuration, the Terminating Resistors are “On” at both ends of the interface. The resistors are on at the NT1 and “On” at the farthest i2022 from the NT1.
Figure 7: Farthest Teleset