12 Chapter 2 1002rp server description
Environmental specifications | Specification |
|
| |||
| Environmental condition |
|
| |||
| Operating temperature | 10 C to 35 C (50 |
| F to 95 |
| F) Maximum |
|
| rate of change must not exceed 10C | ||||
|
| (50F) per hour. | ||||
| ||||||
|
| |||||
| 95%, | |||||
|
|
|
|
|
|
|
| Altitude | 1829 m (6000 ft) |
|
|
|
|
|
|
|
|
|
|
|
| Electrostatic discharge | 15 kV or more |
|
|
|
|
|
|
| ||||
| Acoustic noise | 50 dBA in a typical office ambient | ||||
|
| temperature (18C to 25C [64.4F to | ||||
|
| 77F]) |
|
|
|
|
| Operating shock | No errors with a half sine wave shock | ||||
|
| of 2G (with 1 millisecond duration) | ||||
|
|
| ||||
| Handling drop | Operational after a free fall from 450 | ||||
|
| mm to 600 mm (18 in. to 24 in.) | ||||
|
| (depending on weight) |
|
| ||
|
|
|
|
|
|
|
Front panel features (front view without the front bezel)
The front view of the 1002rp server chassis shows redundant dual fans to the left and the right of the status panel. The left drive bay holds six SCSI hard drives with