Environmental specifications

12 Chapter 2 1002rp server description

Environmental specifications

Specification￿ ￿

￿

 

￿

 

 

Environmental condition

 

 

 

Operating temperature

10 C to 35 C (50

 

F to 95

 

F) Maximum

 

 

rate of change must not exceed 10￿C

 

 

(50￿F) per hour.￿￿

 

Non-operating (storage) temperature

-40 C to 70 C (-40 F to 158 F)

 

 

￿￿

 

Non-operating humidity

95%, non-condensing at 30 C (86 F)

 

 

 

 

 

 

 

 

Altitude

1829 m (6000 ft)

 

 

 

 

 

 

 

 

 

 

 

 

Electrostatic discharge

15 kV or more

 

 

 

 

 

 

 

 

Acoustic noise

50 dBA in a typical office ambient

 

 

temperature (18￿C to 25￿C [64.4￿F to

 

 

77￿F])

 

 

 

 

 

Operating shock

No errors with a half sine wave shock

 

 

of 2G (with 1 millisecond duration)

 

 

 

 

Handling drop

Operational after a free fall from 450

 

 

mm to 600 mm (18 in. to 24 in.)

 

 

(depending on weight)

 

 

 

 

 

 

 

 

 

Front panel features (front view without the front bezel)

The front view of the 1002rp server chassis shows redundant dual fans to the left and the right of the status panel. The left drive bay holds six SCSI hard drives with hot-pluggable carriers. The media drive bay, located to the right, houses the CD-ROM, tape drive, and floppy disk drive.