Connecting the server to the Nortel server subnet (optional) 51
Connecting the server to the Nortel server subnet (optional)
Introduction
This section provides instructions to connect the server to the Nortel server subnet.
Note: The Nortel server subnet is optional. However, a Nortel server subnet is required to support desktop and Web messaging users.
ATTENTION
To comply with EMC radiation requirements, a Class A hub must be located 10 m (33 ft.) away from the 1002rp server. Shielded Ethernet cables must be used.
Media Access Control address
The MAC address is a unique number assigned to network cards and controllers. The procedure below asks you to record the CLAN MAC address. The MAC address is recorded on a label affixed to the back of the chassis.
To connect the server to the Nortel server subnet
Step Action
1See the diagram on page "Rear panel connectors" (page 47) to locate the CLAN network card.
2Locate the MAC address label on the back of the chassis that identifies the CLAN controller MAC address.
3Record the MAC address on the Configuration Wizard worksheet that is provided in the Installation and Configuration Task List
You need the MAC address to identify the CLAN when running the
Configuration Wizard to configure the CallPilot server.
Note: When connecting the optional Nortel server subnet, do not power up unless your antivirus programs and Nortel security updates are installed first.
4Connect an
—End—
What is next?
Continue with "Installing the Nortel software feature dongle" (page 52).
Nortel CallPilot
1002rp Server Hardware Installation
5.0 23 February 2007
Copyright © 2007, Nortel Networks | Nortel Networks Confidential |