Type the number of your choice and press Return:

Select 2 and press Enter.

7See the instructions for installing Disk 1 in this document for more information on what to enter for the following items:

Networked

DHCP

Primary Network Interface

Hostname (You may have to backspace over the word "unknown" and type in the correct name.)

IP Address

Subnet

Netmask

iPV6

Confirm

Security Policy

Confirm

Note: This procedure skips some of the steps for initial installation of CD1.

Regions

Time Zone

Date & Time

Confirm

Password

You will then see System identification is completed.

The system reboots. You can log back in as root.

8At the MgmtSvr, you will see the following message:

You are now configuring the NTP time source for this server. The servers which run the Management and Accounting service will be the source. You will need to provide the Machine Logical IP Address of each server. If running simplex mode, provide the same address twice.

Press the Enter Key to Continue --