9Enter the primary machine physical IP address for the dmfe0 interface: <Physical IP address of the dmfe0 interface>

Example: 120.120.13.23

10Enter the secondary machine physical IP address for the dmfe1 interface:

<Physical IP address of the dmfe1 interface>.

Example: 120.120.13.24

11Enter the <machine logical IP addresses of the servers> that are the ping targets.

Note: Do not enter the IP address of the server you are working on.

IP Multipathing needs a set of reliable hosts to ping against. Select a set of three IP addresses in this subnet that belong to reliable nodes (such as fault tolerant servers). Select the three nodes from the following list, in order of preference:

For IPMP GROUPS:

Machine Logical IP address of the database server

Machine Logical IP address of the Management server

Machine Logical IP address of the CAM server

BPS stack IP address

Other optional devices (PRI Gateway host)

Provide between two and six ping targets or each IPMP group for proper IPMP failover reliability. Enter the address "0.0.0.0" to indicate list is complete, if entering less than six targets.

Note: Do NOT use this server's own IP address as a ping target.

12Press Enter after each IP address, for example: 0.0.0.0 [Enter] (This is the third ping target machine logical IP address.).

Example

Enter ping target #1: 120.120.13.22[Enter]

Enter ping target #2: 120.120.13.1[Enter]

Enter ping target #3: 0.0.0.0 [Enter]

Note: 0.0.0.0 ends the ping target list.

13You will see the configuration summary appear as shown in the following figure:

MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide

Page 61