3.3.16Transformer Assy
(1)Remove the upper cover (see 3.3.4 (1) – (5)).
(2)Remove AC inlet 1 and AC switch 2 from the frame guide.
(3)Disconnect the cable 3 from the connector 4 on the Control/Power Supply Board 5.
(4)Remove a screw 6 and disconnect ground cable 7.
(5)Remove two screws 8 and shift the transformer Assy 9 to the left and remove it.
6
1
8
7
2
9
3
5 4
3 – 20