(3)Head overheat alarm
The voltage of the output TSD signal of the thermistors, one of which is contained in the print head and the other in the print head driver, is monitored by the CPU/AD port to control the voltage
Temp | Stop |
| 119°C |
| Mode up |
| α°C |
| ß°C |
| Mode down |
Mode and print control
Mode | Speed | Pass | Direction |
|
|
|
|
|
|
1 | 100% | 1 | Bi |
|
|
|
|
|
|
2 | 85% | 1 | Bi |
|
|
|
|
|
|
3 | 70% | 1 | Bi |
|
|
|
|
|
|
4 | 55% | 1 | Bi |
|
|
|
|
|
|
5 | 40% | 1 | Bi |
|
|
|
|
|
|
6 | 30% | 1 | Bi | 1.5 Sec Stop |
|
|
|
|
|
(7) | Stop |
|
|
|
|
|
|
|
|
|
|
|
|
|
•When the temperature is between α°C and 119°C, the mode switches sequentially to higher level. When the temperature falls below ß°C, the mode switches to lower level.
•When the temperature exceeds 119°C, printing will stop.
•When temperature gradient is steep, higher mode shall be specified directly.
2 – 18