(3)Fatal Alarm

Table 6.3 (1/2)

ALARM

CATEGORY

MAIN CONTROL

LED DISPLAY

 

ALARM

REMARKS

ALARM 10 12 15 17 20

PROP HSD UTL NLQ

MPU internal

Read/write error

RAM alarm

 

Program ROM

Check sum error

alarm

 

TROUBLESHOOTING

Replace Control/ Power Supply Board

Replace ROM or Con- trol/Power Supply Board

6 – 3

ALARM

FIRMWARE DETECTION ALARM

RAM on Control Board alarm

EEPROM alarm

WDT (Watch Dog Timeout) alarm

NMI signal alarm

BRK instruction alarm

MPU internal RAM alarm

Read/write error

No reaction when MPU reads data

MPU is locked up and it ios reset after 65ms.

NMI port of MPU is kept low level.

FFFFdata is detected due to MPU locked up. Read/write error

Replace Control/

Power Supply Board

Replace Control/

Power Supply Board

Turn the power OFF and ON or replace Control/ Power Supply Board

Turn the power OFF and ON or replace Control/ Power Supply Board Replace ROM or Con- trol/Power Supply Board Replace I/F Board

SERIAL INTERFACE ALARM

ROM alarm

Check sum error

 

RAM on I/F board

Read/write error

alarm

 

I/F not mounted

No reaction from

serial I/F board

 

 

: LED Blink (200ms ON, 200ms OFF)

 

: LED Lights up

Replace ROM on I/F board or I/F Board Replace I/F Board

Replace I/F Board or Control Board.

Page 106
Image 106
Oki 3321, 3320 specifications 1/2