9600 Compressor Installation, Operation, and Maintenance

General

CTI-CRYOGENICS

HELIX TECHNOLOGY CORPORATION

The information in Table 1-4 provides general Compressor operating specifications.

Table 1-4: General Compressor Operating Specifications

Specification

 

Values

 

 

 

Part Numbers

 

 

 

 

 

Input Power Cable

 

600 VAC

(Customer Supplied)

 

10 Gauge, 3 conductor wire with ground

 

 

Must conform to local electrical codes

 

 

 

Nominal Helium Pressure

 

Refer to Table 4-1

 

 

 

Ambient Operating

 

50 - 100º F (10 - 38º C)

Temperature Range

 

 

 

 

 

Interface

 

Cryopump Power Receptacles: mates with the

 

 

CTI-CRYOGENICS supplied cryopump power cable for

 

 

single pump use.

 

 

Mates with remote junction box power cable for multiple

 

 

cryopump use.

Gas Supply Connector

 

1/2 in. Aeroquip self-sealing coupling

Gas Return Connector

 

1/2 in. Aeroquip self-sealing coupling

Remote Control Receptacle

 

24VAC, 2.7A inductive mates with P5 connector P/N

 

 

MS3106A*

 

 

 

Adsorber Service Schedule

 

3 Years

 

 

 

 

* Supplied by CTI-CRYOGENICS

 

 

 

NOTE: The 9600 Compressor is designed for continuous operation and should remain ON when the cryopumps are in a regeneration cycle.

P/N 8040540

1-7

Page 14
Image 14
Olicom 9600 manual General Compressor Operating Specifications