9600 Compressor Installation, Operation, and Maintenance

CTI-CRYOGENICS

 

 

 

 

 

 

 

 

HELIX TECHNOLOGY CORPORATION

 

 

Table C-1: Compressor Troubleshooting Procedures (Continued)

 

 

 

 

 

 

 

 

 

 

Problem

 

Possible Cause

 

Corrective Action

 

 

 

 

 

 

 

 

 

3) System circuit breaker

1)

Damaged On-Board

1)

Check for compressor

 

 

 

(CB1) will not remain in

 

power cable, connectors,

 

operation with cryopump

 

 

 

the ON (1) position

 

or drive motor.

 

cable disconnected from

 

 

 

when switched ON. The

 

 

 

compressor. Refer to

 

 

 

Control Circuit circuit

 

 

 

Appendix A to contact

 

 

 

breaker (CB2) trips

 

 

 

the Customer Support

 

 

 

when excessive current

 

 

 

Center if the compressor

 

 

 

is being drawn by the

 

 

 

operates improperly.

 

 

 

cold head or 24 volt

 

 

 

 

 

 

 

 

 

compressor control cir-

2)

Damaged component in

2)

Refer to Appendix A to

 

 

 

cuits.

 

the compressor power or

 

contact the Customer

 

 

 

 

 

control circuit.

 

Support Center.

 

 

 

 

 

 

 

 

 

 

4)

System circuit breaker

1)

Thermal protective

1)

Check for inadequate

 

 

 

(CB1) remains in the ON

 

switches are open.

 

water cooling. Refer to

 

 

 

(1) position and the com-

 

 

 

Table 1-3.

 

 

 

pressor stops after sev-

 

 

 

 

 

 

 

 

 

eral minutes of operation

2) Very cold water has caused

2)

Recheck for proper cool-

 

 

 

and remains OFF (0).

 

a restriction of oil flow

 

ing water temperature.

 

 

 

 

 

through the oil injection

 

Refer to Table 1-3.

 

 

 

 

 

orifice during start-up.

 

Restart compressor

 

 

 

 

 

 

 

repeatedly until continu-

 

 

 

 

 

 

 

ous operation is achieved.

 

 

 

 

 

 

 

 

 

 

5)

System circuit breaker

1)

Loss or degradation of

1)

Check that line voltage is

 

 

 

(CB1) trips after a period

 

power from the source.

 

correct on all phases.

 

 

 

of running.

 

 

 

 

 

 

 

 

 

 

2)

Defective motor windings.

2)

Check running current on

 

 

 

 

 

 

 

all phases.

 

 

 

 

 

 

3)

Refer to Appendix A to

 

 

 

 

 

 

 

contact the local Cus-

 

 

 

 

 

 

 

tomer Support Center.

 

 

 

 

 

 

 

 

6) All cryopumps making

1) Cryopump power phase

1)

Set power phase switch in

 

 

 

loud noise.

 

switch is in the wrong

 

opposite position.

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P/N 8040540

C-3