9600 Compressor Installation, Operation, and Maintenance
CTI-CRYOGENICS
HELIX TECHNOLOGY CORPORATION
Supply and Return Water Line Connections
NOTE: The water used for cooling the Compressor must meet the specifications outlined in Section 1 - Compressor Description.
Hard Water Lines
1.Apply a light coating of standard plumbing thread sealant to the hard line pipe threads.
2.Install the Supply hard line into the INPUT connection on the rear panel of the Compressor. Tighten the fitting by hand.
3.Install the Return hard line into the OUTPUT connection on the rear panel of the Compressor. Tighten the fitting by hand.
CAUTION
Do not overtighten the ferrules. Damage to the input and output connector threads may occur.
4.Using a wrench, tighten the fittings.
5.Allow water to flow and check for leaks at the rear of the Compressor.
Flexible Water Lines
1.Apply a light coating of standard plumbing thread sealant to the barbed fitting threads.
2.Install the barbed fittings into the INPUT and OUTPUT connections on the rear panel of the Compressor.
CAUTION
Do not overtighten the barbed fittings. Damage to the INPUT and
OUTPUT connector threads may occur.
3.Using a wrench, tighten the barbed fittings.
4.Connect the Supply flexible water line to the INPUT barbed fitting and secure with a hose clamp.
5.Connect the Return flexible water line to the OUTPUT barbed fitting and secure with a hose clamp.
6.Allow water to flow and check for leaks at the rear of the Compressor.
P/N 8040540 |