Controls and their functions
<Front Panel Bottom Section>
%0VIDEO IN LEVEL control and switch These are used to adjust the video input level.
PRESET: When the switch is set to “PRESET”, the video input level is set to the unity value (0 dB).
MANUAL: When the switch is set to “MANUAL”, the video input level can be adjusted using this control.
%1VIDEO OUT LEVEL control and switch
When setup menu No. 10 (ENCODER SEL) is set to “LOCAL”, the video output level can be adjusted.
When the switch is set to “PRESET”, the video output level is set to the unity value (0 dB). When the switch is set to “MANUAL”, the video output level can be adjusted using this control.
%2CHROMA LEVEL control and switch
When setup menu No. 10 (ENCODER SEL) is set to “LOCAL”, the chroma level can be adjusted.
When the switch is set to “PRESET”, the chroma level is set to the unity value (0 dB). When the switch is set to “MANUAL”, the chroma level can be adjusted using this control.
%3BLACK LEVEL control and switch
When setup menu No. 10 (ENCODER SEL) is set to “LOCAL”, the black level can be adjusted.
When the switch is set to “PRESET”, the black level is set to the unity value (0 IRE). When the switch is set to “MANUAL”, the black level can be adjusted using this control.
%4CHROMA PHASE control and switch
When setup menu No. 10 (ENCODER SEL) is set to “LOCAL”, the chroma phase can be adjusted.
When the switch is set to “PRESET”, the chroma phase is the unity value (0°).
When the switch is set to “MANUAL”, the chroma phase can be adjusted using this control.
%5CF switch
This selects whether the playback framing is to be locked in
4F/8F: 625 mode: The framing is locked in 4- or
525 mode: The framing is locked in
2F: The framing is locked in
%6TC generator switch
REGEN: When the REGEN/PRESET switch is at REGEN, the internal time code generator is synchronized with the time code which the time code reader read from the tape. Whether to set TC or UB to REGEN can be selected at the setup menu No. 503 (TCG REGEN).
PRESET: When the REGEN/PRESET switch is at PRESET, presetting is enabled by the controls on the operation panel or by remote control.
REC RUN: The time code runs only during recording when the RUN MODE switch has been set to REC. The time code runs constantly when the REGEN/PRESET switch is set to REGEN.
FREE RUN: The time code runs regardless of the operation mode as long as the power is being supplied when the RUN MODE switch has been set to FREE.
ENGLISH
15 (E)