Setup menus

Lock mode can be set to protect the settings in the system files and user files (USER2 – USER5). Settings can no longer be changed when this mode is set.

To set and release the lock mode for the system files and user files use setup item No. 30 (MENU LOCK) and setup menu item No. A03 (MENU LOCK), respectively.

Setting and releasing the lock mode.

1

2

Press the MENU button.

While holding down the STAND BY button, press the REW or FF button, and select the file for which the lock mode is to be set or released.

3

4

Turn the search dial and move the cursor ( ) on the menu screen to setup item No. 30 (MENU LOCK) or setup menu item No. A03 (MENU LOCK) for the system or user file.

While holding down the search button, turn the search dial and select lock mode setting or release.

To set the lock: Select the 0001 (ON) setting.

To release the lock: Select the 0000 (OFF) setting.

When the lock has been set, “LOCKED” flashes on the menu screen. In addition, the counter display stops flashing and lights.

 

 

 

 

 

 

SETUP-MENU

 

LOCKED

 

 

<USER2>

 

No.800

– 0005

000

P–ROLL TIME

5s

001

LOCAL ENA

ST&EJ

002

TAPE TIMER

±12h

003

REMAIN SEL

OFF

004

SETUP

NUMBER

OFF

005

METER

SELECT

CUE

006

SYNCHRONIZE

OFF

007

SUPER

 

 

 

ON

008

DISPLAY SEL

T&STA

 

 

 

 

 

 

5

Press the SET button. The setting is now stored in the memory.

<Notes>

The lock mode cannot be set for the USER1 file settings.

Even if the RESET button is pressed, the files which has been set to the lock mode cannot be reset to the factory settings.