Setup menus
USER menu
<INTERFACE>
| Item |
| Setting |
| |||||
|
|
|
|
|
|
|
|
| Description |
No. | Superimposed | No. |
| Superimposed | |||||
display |
|
|
| display |
| ||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
200 | PARA RUN | 0000 |
|
|
| DIS | This selects whether two or more VTRs are to be operated in | ||
|
| 0001 |
|
|
| ENA |
| synchronization. | |
|
|
|
|
|
|
|
|
| 0: No operation in synchronization |
|
|
|
|
|
|
|
|
| 1: Operation in synchronization |
|
|
|
|
|
|
|
|
| <Note> |
|
|
|
|
|
|
|
|
| When operating two or more VTRs in synchronization, set all |
|
|
|
|
|
|
|
|
| the VTRs to 0001 (ENA). |
|
|
|
|
|
|
|
|
|
|
201 | 9P SEL | 0000 |
|
|
| OFF | This selects whether the 9P connector functions when the | ||
|
| 0001 |
|
|
| ON | REMOTE/LOCAL switch has been set to REMOTE. | ||
|
|
|
|
|
|
|
|
| 0: Do not function |
|
|
|
|
|
|
|
|
| 1: Function |
|
|
|
|
|
|
|
|
|
|
202 | ID SEL | 0000 |
|
|
| OTHER |
| This selects the ID information which is returned to the | |
|
| 0001 |
|
|
| DVCPRO | controller. | ||
|
|
|
|
|
|
|
|
| 0: 20 25H = 525 mode; 21 25H = 625 mode |
|
|
|
|
|
|
|
|
| 1: The DVCPRO’s original ID (F0 33H = 525 mode; F1 33H = |
|
|
|
|
|
|
|
|
| 625 mode) is returned. |
|
|
|
|
|
|
|
|
|
|
203 | 25P SEL | 0000 |
|
|
| OFF | This selects whether the PARALLEL (25P) connector functions | ||
|
| 0001 |
|
|
| ON | when the REMOTE/LOCAL switch has been set to REMOTE. | ||
|
|
|
|
|
|
|
|
| 0: Does not function |
|
|
|
|
|
|
|
|
| 1: Functions |
|
|
|
|
|
|
|
|
|
|
204 | RS232C SEL | 0000 |
|
|
| OFF | These settings are for selecting whether the | ||
|
| 0001 |
|
|
| ON |
| connector is to function when the REMOTE/LOCAL switch is | |
|
|
|
|
|
|
|
|
| set to REMOTE. |
|
|
|
|
|
|
|
|
| 0: Connector does not function. |
|
|
|
|
|
|
|
|
| 1: Connector functions. |
|
|
|
|
|
|
|
|
| |
205 | BAUD RATE | 0000 |
| 300 |
|
| These settings are for selecting the | ||
|
| 0001 |
| 600 |
|
| speed (baud rate). | ||
|
| 0002 |
| 1200 |
|
|
| ||
|
| 0003 |
| 2400 |
|
|
| ||
|
| 0004 |
| 4800 |
|
|
| ||
|
| 0005 |
|
| 9600 |
|
| ||
|
|
|
|
|
|
|
| ||
206 | DATA | 0000 |
| 7 |
|
| These settings are for selecting the | ||
| LENGTH | 0001 |
|
| 8 |
| (Unit: bit) | ||
|
|
|
|
|
|
| |||
207 | STOP BIT | 0000 |
|
| 1 |
| These settings are for selecting the | ||
|
| 0001 |
| 2 |
|
| (Unit: bit) | ||
|
|
|
|
|
|
|
| ||
208 | PARITY | 0000 |
|
|
| NON |
| These settings are for selecting the none, odd or even for the | |
|
| 0001 |
|
|
| ODD | |||
|
| 0002 |
|
|
| EVEN | 0: Parity bit is not used. | ||
|
|
|
|
|
|
|
|
| 1: An odd number of bits is used for the parity system. |
|
|
|
|
|
|
|
|
| 2: An even number of bits is used for the parity system. |
|
|
|
|
|
|
|
| ||
209 | RETURN | 0000 |
|
|
| OFF | These settings are for selecting whether the ACK code is to be | ||
| ACK | 0001 |
|
|
| ON | returned when a command is received from | ||
|
|
|
|
|
|
|
|
| 0: ACK code is not returned. |
|
|
|
|
|
|
|
|
| 1: ACK code is returned. |
|
|
|
|
|
|
|
| ||
210 | 25P STBY | 0000 |
|
|
| OFF/ON | For selecting the method used to detect the STANDBY | ||
| CMD | 0001 |
|
|
| ON |
| COMMAND signal input at the PARALLEL (25P) connector. | |
|
|
|
|
|
|
|
|
| 0: Each time active signals are detected, the STANDBY ON or |
|
|
|
|
|
|
|
|
| STANDBY OFF mode is selected alternately. |
|
|
|
|
|
|
|
|
| 1: When active signals are detected in the STANDBY OFF |
|
|
|
|
|
|
|
|
| mode, the unit is transferred to the STANDBY ON mode. |
|
|
|
|
|
|
|
|
| Nothing happens if they are detected during an operation in |
|
|
|
|
|
|
|
|
| the STANDBY ON mode. |
|
|
|
|
|
|
|
|
|
|
The underline on the setting item denotes the initial setting.
68 (E)