7
Chapter 7 Menu description tables
95
NP-L50 2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
12.4
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
ENDURA50*12
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
12.4
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
Item/
Data storage
Variable
range Remarks
The underlining in the variable range column indicates the setting in the preset mode.
CUF
CUF
ENDURA80*12
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
13.2
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
CUF
ENDURA-D*22
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
13.2
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
CUF
*1 Select the ENDURA50 or ENDURA80 item if the V-mount adapter plate is
to be installed and the ENDURA battery is to be used while the battery
holder made by Anton Bauer remains in place.
*2 Select ENDURA-D if the battery holder is to be changed to the IDX made
battery holder, and ENDURA80 is to be used instead. It is then possible to
display the percentage of the remaining charge of the ENDURA80 battery.
Item/
Data storage
Variable
range Remarks
BP-L60/90 2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
11.3
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
CUF
NP-1B 2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO: The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0
:
11.3
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
CUF
<Note>
In the case of a digital battery (DIGITAL14, DIGITAL13, NP-L50D, DIONIC or ENDURA-D), the remaining battery chargedisplayed in the viewfinder appears as a percentage.What is displayed to warn the user that the end of theremaining battery charge is approaching is determined by thesetting on the <BATTERY SETTING> screen regardless ofthe percentage display.