Chapter 7 Menu description tables
96
Item/
Data storage
Variable
range Remarks
7-8-4 BATTERY SETTING2
DIGITAL14 2
/
11.0
:
13.5
:
15.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to considered
nearly depleted.
11.0
:
13.2
:
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
DIGITAL13 2
/
11.0
:
12.3
:
15.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to considered
nearly depleted.
11.0
:
11.8
:
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
DIONIC 2
/
11.0
:
13.6
:
15.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to considered
nearly depleted.
11.0
:
13.1
:
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
NEAR END
END
NEAR END
END
NEAR END
END
The underlining in the variable range column indicates the setting in the preset mode.
CUF
CUF
CUF
NP-L50D 2
/
11.0
:
12.4
:
15.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to considered
nearly depleted.
11.0
:
11.6
:
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
NEAR END
END
CUF
TYPE A 2
/
11.0
:
13.5
:
15.0
12.0
:
15.0
:
17.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
nearly depleted.
For selecting in 0.1 V steps the voltage at
which FULL is to be displayed.
11.0
:
12.6
:
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
Item/
Data storage
Variable
range Remarks
TYPE B 2
/
11.0
:
13.0
:
15.0
12.0
:
15.2
:
17.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2:The selection is enabled.
/:The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
nearly depleted.
For selecting in 0.1 V steps the voltage at
which FULL is to be displayed.
11.0
:
12.4
:
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
NEAR END
FULL
END
NEAR END
FULL
END
CUF
CUF