Installation (The installation work must be performed by your dealer without fail.)

$ Transmission signal selection setting

The switches on the COMP and CONNECTOR printed circuit boards must be set to correspond to the signals to be transmitted and components to be connected to the pan/tilt head.

(When shipped, the analog settings are supported.)

OAnalog/IEEE1394 card settings

OWEB card settings

SDI/PR switch:

PR

SDI/PR switch:

PR

WEB/1394 switch:

1394

WEB/1394 switch:

WEB

WEB/RP 422 switch: RP 422

WEB/RP 422 switch: WEB

OSDI settings

 

 

 

SDI/PR switch:

SDI

 

 

WEB/1394 switch:

1394

 

 

WEB/RP 422 switch:

RP 422

 

 

COMP switch

SDI/PR switch

PB switch

Do not change the setting of this switch — use it at the PB position.

COMP printed circuit board

WEB/1394 switch

WEB/RP 422 switch

CONNECTOR printed circuit board

<Note>

OBefore setting the switches, make absolutely sure that the power of the AC adapter which is to be connected to the pan/tilt head is set to OFF.