Installation (The installation work must be performed by your dealer without fail.)
$ Setting the cable compensation circuit of video signals
(COMP switch of the COMP printed circuit board is set to “OFF” in the default setting.)
1When using the
When this controller (or multiport hub) has been connected to the pan/tilt head, it is permissible for the connecting cables to be up to 1640 ft. (500 m) long when a
1.Remove the four screws on the base connector rear panel, and pull out the panel toward you.
2.Set the COMP switch on the COMP printed circuit board at the back of the panel to “1”.
3.Return the panel to its original position and secure it in place using the four screws.
2When using the AW-RP605A controller
When this controller has been connected to the pan/tilt head, it is permissible for the connecting cables to be up to 3333 ft. (1000 m) long when a
1.Remove the four screws of the base connector rear panel, and pull out the panel toward you.
2.Set the COMP switch on the COMP printed circuit board at the back of the panel to “2”.
3.Return the panel to its original position and secure it in place using the four screws.
3When using the AW-RP400 controller
When this controller has been connected to the pan/tilt head, it is permissible for the connecting cables to be up to 1640 ft. (500 m) long when a
Since the
4When using a personal computer as the controller (for transmissions using component signals) and the configuration described in 1
A separate cable compensation unit is required if the cables used to connect the pan/tilt head and controller are to be run over a long distance.
<Note>
OBefore setting the switches, make absolutely sure that the power of the AC adapter which is to be connected to the pan/tilt head is set to OFF.