1.To set the upper limit position of the travel range:

Using the controller, tilt the camera to the position which is to serve as the upper limit.

While holding down the MENU/LIMIT button on the controller, press PRESET MEMORY button 15 Manual background .

The setting is completed as soon as the lamp of the PRESET MEMORY button 45 comes on.

To release the setting:

While holding down the MENU/LIMIT button on the controller, press PRESET MEMORY button 15 Manual background .

The setting is released when the lamp of the PRESET MEMORY button 50 comes on.

3.To set the left-most limit position of the travel range:

Using the controller, tilt the camera to the position which is to serve as the left- most limit.

While holding down the MENU/LIMIT button on the controller, press PRESET MEMORY button 5 Manual background .

The setting is completed as soon as the lamp of the PRESET MEMORY button 45 comes on.

To release the setting:

While holding down the MENU/LIMIT button on the controller, press PRESET MEMORY button 5 Manual background .

The setting is released when the lamp of the PRESET MEMORY button 50 comes on.

2.To set the lower limit position of the travel range:

Using the controller, tilt the camera to the position which is to serve as the lower limit.

While holding down the MENU/LIMIT button on the controller, press PRESET MEMORY button 20 Manual background .

The setting is completed as soon as the lamp of the PRESET MEMORY button 45 comes on.

To release the setting:

While holding down the MENU/LIMIT button on the controller, press PRESET MEMORY button 20 Manual background .

The setting is released when the lamp of the PRESET MEMORY button 50 comes on.

4.To set the right-most limit position of the travel range:

Using the controller, tilt the camera to the position which is to serve as the right-most limit.

While holding down the MENU/LIMIT button on the controller, press PRESET MEMORY button 10 Manual background .

The setting is completed as soon as the lamp of the PRESET MEMORY button 45 comes on.

To release the setting:

While holding down the MENU/LIMIT button on the controller, press PRESET MEMORY button 10 Manual background .

The setting is released when the lamp of the PRESET MEMORY button 50 comes on.