Connections

:When the pan/tilt head is to be controlled by the AW-RP400 pan/tilt head control panel for transmitting SDI signals (and the AW-CB400 remote operation panel is used to control the camera)

Coaxial cable

Camera cable

Remote operation

 

(supplied)

panel:

 

 

AW-CB400

 

 

 

Cable supplied

 

Pan/tilt control panel:

with AW-CB400

 

 

 

AW-RP400

 

10BASE-T (equivalent to UTP category 5) straight cable, max. 1640 ft. (500 m)

DC cable

(UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG, to be locally purchased)

AC adapter:

AW-PS300A

Coaxial cable (BELDEN 8281), max. 666 ft. (200 m)

Color monitor

Use the supplied camera cable to connect the unit with the convertible camera containing the plugged-in SDI card (such as the AW-PB504N).

Use a coaxial cable to connect the SDI card’s SDI OUT connector with the unit’s SDI IN connector. Adjust the cable to a length at which the pan/tilt head will move smoothly.

Set controller selection switch SW1 to the right side (RP501), and select the transmission signal selection setting that supports the SDI card.

Use a 10BASE-T straight cable (UTP category 5) to connect the unit’s CONTROL IN IP/RP connector with the controller’s CONTROL OUT TO PAN/TILT HEAD connector.

Use a coaxial cable to connect the unit’s Pr/SDI OUT connector with the color monitor’s SDI input connector.

Use the cable supplied with the remote operation panel to connect the controller’s CAMERA CONTROL IN FROM ROP connector with the remote operation panel’s CONTROL OUT TO CONTROL PANEL connector.

Check that the pan/tilt head and camera can be controlled by the controller.