Connections

$ Connecting the AC adapter for use with the pan/tilt head

Connect the pan/tilt head with the AW-PS300A AC adapter designed for use with the pan/tilt head.

Standard bare end length 11 mm

It is recommended that the tip be soldered.

AC adapter for use with the pan/tilt head: AW-PS300A

>DC 12V IN terminal board

Connect this to the DC 15V OUT connector on the AC adapter (AW-PS300A). (The voltage output from the AC adapter is set to 15V: this takes into consideration the voltage drops due to the possible extension of the DC cable between the pan/tilt head and AC adapter.)

Make sure that the positive + and negative - ends of the wires are connected to the same signs on the connector.

Use a cable with a nominal cross section of 1.25 mm2 or more that meets the UL specifications for the connection. The maximum allowable cable length is 98.4 ft. (30 meters).

Applicable (usable) wire

UL Type SPT-2 2!16 AWG or UL Type NISPT-2 2!16 AWG

?LAMP CONTROL terminal board

Connect this only when the power of a halogen lamp is to be supplied from the AC adapter (AW-PS300A).

This connector is connected to LAMP

CONTROL on the AC adapter for the pan/tilt head.

The symbols C and S on the wires must match the same symbols on the connector.

Use a cable with a nominal cross section of 0.3 mm2 or more that meets the UL specifications for the connection. The maximum allowable cable length is

98.4ft. (30 meters).

@OP terminal board

Connect this only when the OP SW CONTROL OUT connector on the AC adapter (AW-PS300A) is to be used. Connect it to the OPTION SW CONTROL IN connector on the AC adapter (AW-PS300A).

Use a cable with a nominal cross section of 0.3 mm2 or more that meets the UL specifications for the connection. The maximum allowable cable length is

98.4ft. (30 meters).

- 26 -

Page 26
Image 26
Panasonic AW-PH360N manual $ Connecting the AC adapter for use with the pan/tilt head, DC 12V in terminal board