Tally settings

The unit can receive the tally information of the switcher and other external devices from the TALLY/GPI connector (TALLY input) on the rear panel and two network lines.

To enable turning on the camera status indicators on the unit and the tally lamps on the remote cameras based on the received tally information, you need to configure the following settings.

„„Registering the camera numbers that will correspond to the tally inputs

Setting is required to use TALLY IN1 to TALLY IN10 signals from the TALLY/GPI connector (TALLY input) on the rear panel.

Refer to the relevant explanation in this section.

„„Registering the camera numbers that will correspond to the image inputs of the switcher

Setting is required to use tally information received via the network. Refer to “Setting linking with a switcher” (page 31).

„„Setting the sending of tally information from the unit to remote cameras

Refer to the relevant explanation in this section.

„„Settings on remote cameras

Setting is required on the remote camera to enable turning on the tally lamp.

Refer to the operating instructions for the remote camera.

Registering the camera numbers that will correspond to the tally inputs

1. Press the MENU button..

2. Open TALLY menu [44]..

3. Turn the F1 dial to select the TALLY input connector number..

1.TALLY IN1

CAM1

Input connector number : Select form TALLY IN1 to TALLY IN10

4.Turn the F2 dial to select the corresponding camera number, and then press the F2 dial to confirm the selection..

Camera number : Select from CAM1 to CAM100.

Setting the sending of tally information from the unit to remote cameras

1.Press the MENU button..

2.Open CAMERA SETUP menu [24]..

3.Turn the F1 dial to display the “3.  TALLY OUT” item..

3.TALLY OUT

Off

4.Turn the F2 dial to select “On” or “Off”, and then press the F2 dial to confirm the selection..

On

: Sends tally information to remote cameras.

Off

: Does not send tally information to remote cameras.

39

Page 39
Image 39
Panasonic AWRP120GJ operating instructions Tally settings, „„Settings on remote cameras, Tally IN1, Tally OUT