Table of setting items (menus)

Button

Menu name

Setting item

Remote camera

 

Initial value on

Setting

number

 

unit (*1)

 

 

 

 

 

[21]

SHUTTER

1. SHUTTER

AW‑HE120

 

Off, Step, Synchro, ELC

 

 

 

AW‑HE50, AW‑HE60

 

Off, Step, Synchro

 

 

 

AW‑HE2

 

“---”

 

 

 

AW‑HE100

 

Off, Step, Synchro

 

 

 

AW‑HE870

 

Off, Step, Synchro, ELC

 

 

 

AW‑E860, AW‑E750,

 

Off, Step, Synchro, ELC

 

 

 

AW‑E650, AW‑E350

 

 

 

 

 

 

AK‑HC1500, AK‑HC1800

 

Off, Step, Synchro

 

 

2. SPEED

AW‑HE120

 

59..94 Hz:

 

 

 

 

 

 

1/100, 1/250, 1/500, 1/1000, 1/2000,

 

 

 

 

 

 

1/4000, 1/10000

 

 

 

 

 

 

50 Hz:

 

 

 

 

 

 

1/120, 1/250, 1/500, 1/1000, 1/2000,

 

 

 

 

 

 

1/4000, 1/10000

 

 

 

AW‑HE50, AW‑HE60

 

1/100, 1/250, 1/500, 1/1000, 1/2000,

 

 

 

 

 

 

1/4000, 1/10000

 

 

 

AW‑HE2

 

“---”

 

 

 

AW‑HE100

 

1/100, 1/250, 1/500, 1/1000, 1/2000

 

 

 

AW‑HE870

 

1/100, 1/250, 1/500, 1/1000, 1/2000,

 

 

 

 

 

 

1/4000, 1/10000

 

 

 

AW‑E860, AW‑E750,

 

1/100, 1/250, 1/500, 1/1000, 1/2000,

 

 

 

AW‑E650, AW‑E350

 

 

1/4000, 1/10000

 

 

 

AK‑HC1500, AK‑HC1800

 

VIDEO:

 

 

 

 

 

 

1/100, 1/120, 1/250, 1/500, 1/1000,

 

 

 

 

 

 

1/2000

 

 

 

 

 

 

FILM:

 

 

 

 

 

 

180.0, 172.8, 144.0, 120.0, 90.0, 45.0

[22]

ND FILTER

1. ND FILTER

 

 

ND1, ND2, ND3, ND4

 

 

 

 

 

 

(Only when AW-HE870, AW-E860,

 

 

 

 

 

 

AW-E750, AW-E650, or AW-E350 is

 

 

 

 

 

 

connected)

 

 

 

 

 

 

Off, On

[23]

FUNCTION

2. DEFROSTER

 

 

Off, On

 

 

3. WIPER

 

 

Off, On

 

 

4. HEATER/FAN

 

 

Off, On

[24]

CAMERA SETUP

1. CAM POWER

 

 

GROUP ON

GROUP OFF, GROUP ON, ALL OFF,

 

 

 

 

 

 

ALL ON

 

 

2. AUTO ON

 

 

On

On, Off

 

 

3. TALLY OUT

 

 

Off

On, Off

 

 

4. HOME POSITION

 

 

SET

SET

[25]

RP SETUP

1. FOCUS/IRIS

 

 

STANDARD

STANDARD, EXCHANGE

 

 

2. P/T CURV

 

 

1

1 to 5

 

 

3. LCD BACKLIGHT

 

 

On

On, Off, 60, 120, 180

 

 

4. ENABLE BUTTON

 

 

ACTIVE

ACTIVE, LOCK

 

 

5. MENU CONTROL

 

 

ACTIVE

ACTIVE, LOCK

 

 

6. GLOBAL AREA

 

 

Off

On, Off

 

 

7. IP ADDRESS

 

 

192.168.0.9

 

 

 

8. SUBNETMASK

 

 

255.255.255.0

 

 

 

9. GATEWAY

 

 

192.168.0.1

 

 

 

10. MAC ADDRESS

 

 

 

Displayed only

 

 

11. PORT CAM1

 

 

61000

61000 to 65534

 

 

 

 

 

110. PORT CAM100

 

61000

61000 to 65534

[26]

PAN DIRECTION

1. CAM1

 

 

NORMAL

NORMAL, REVERSE

 

 

 

 

 

 

100. CAM100

 

 

NORMAL

NORMAL, REVERSE

[27]

TILT DIRECTION

1. CAM1

 

 

NORMAL

NORMAL, REVERSE

 

 

 

 

 

 

100. CAM100

 

 

NORMAL

NORMAL, REVERSE

[28]

ZOOM DIRECTION

1. CAM1

 

 

NORMAL

NORMAL, REVERSE

 

 

 

 

 

 

100. CAM100

 

 

NORMAL

NORMAL, REVERSE

[29]

FOCUS DIRECTION

1. CAM1

 

 

NORMAL

NORMAL, REVERSE

 

 

 

 

 

 

100. CAM100

 

 

NORMAL

NORMAL, REVERSE

(*1) “–” indicates a setting saved to the remote camera.

A diagonal line indicates a setting that can only be displayed. It cannot be changed.